Show Sidebar

Surge Protection Devices

Showing 13–18 of 18 results

  • Citel-CXC06-B/FM

    Network
    coaxial DC-70 MHz
    Nominal line voltage
    Un 6 V
    Max. DC operating voltage
    Uc 8 Vdc
    Max. frequency
    f max. DC-70 MHz
    Insertion loss
    ≤0.6 dB
    Return loss
    ≥20 dB
    Impedance
    50 ohms
    VSWR
    < 1.5:1
    Max. load current
    @25°C
    IL 0.5 A
    Operating current
    Continious current at Uc
    Ic None
    Max. discharge current
    max. withstand @ 8/20 µs by pole
    Imax 10 kA
    Protection level
    @ In (8/20 µs)
    Up L/L 25V / 600V
    Impulse current
    2 x 10/350µs Test – D1 Category
    Iimp 2.5 kA / 10 kA
    Nominal discharge current
    C2 Category
    In 5 kA
    Max Power
    6 W
    DC Pass
    Yes
  • Citel-DAC50S-31-275

    The pluggable surge protectors Type 2 DAC50, are designed to protect AC powerline at the main switchboard of the installation. These SPDs are based on high energy varistor equipped with thermal disconnector and failure indicator, to comply with standards and to provide a maximum protection efficiency, a high impulse current capability and an improved reliability. The surge protectors DAC50 are available in multipolar version and in several voltages to protect single or 3-phase networks.

  • Citel-DLA-48DBC

    Network
    Fipway, WorldFIP, FieldBus-h2
    Nominal line voltage
    Un 48 V
    Max. DC operating voltage
    Uc 53 Vdc
    Max. frequency
    f max. > 20 MHz
    Insertion loss
    < 1 dB
    Max. load current
    @25°C
    IL 300 mA
    Max. discharge current
    max. withstand @ 8/20 µs by pole
    Imax 20 kA
    Line inductance
    No
    Protection level
    @ In (8/20 µs)
    Up L/L 75 V
    Impulse current
    2 x 10/350µs Test – D1 Category
    Iimp 5 kA
    Nominal discharge current
    C2 Category
    In 5 kA
    Line resistance
    < 4.7 Ohm
  • Citel-DLC-06D3

    • High speed data transmission
    • Common mode and differential mode protection
    • Data lines, including those isolated from Earth
    • Compact DIN rail enclosure, high density protection
    • Protection of shield wire
    • Location and test categories: D1, C2, C3
    • IEC 61643-21 compliance
  • Citel-MJ8-CAT6S

    Network
    Gigabit Ethernet, Cat.6 cabling
    Max. DC operating voltage
    Uc 8 Vdc
    Max. frequency
    f max. > 250 MHz
    Max. data rate
    10/100/1000 Mbps
    Insertion loss
    < 1 dB
    Max. load current
    @25°C
    IL 1000 mA
    Max. capacitance
    C < 25 pF
    Impulse current
    2 x 10/350µs Test – D1 Category
    Iimp 500 A
    Nominal Discharge Current, X-C (Line/Earth)
    8/20µs Test x 10 – C2 Category
    In L/PE 2000 A
  • DACN1-25VGS-30-760

    Type 1 + 2+3 AC surge protector
    VG Technology
    In: 35 kA
    Iimp: 25 kA on 10/350µs impulse
    No leakage current
    Unpluggable module for each phase
    Remote signaling
    Optimized to TOV
    EN 61643-11, IEC 61643-11 complied