  • Helukabel Thermocouple

    Description Self-extinguishing / Flame retardant
    Cable Structure Core 2
    Size 1.5 mm.
    Ground NO
    Conductor Fe-CuNi (Ko)
    Insulation PVC
    Core Identification Green / White
    Application For temperature measuring, the temperature-dependent characteristics of material are taken into consideration, for example, the expansion thermometers of thermocouples, etc. temperature measuring devices with a thermocouple as transducer usually consist of thermocouple, the connecting line from the connecion point to the reference junction, a reference junction with a known temperature and a voltage mesuring device, the connecting line between the thermocouple and the reference junction must have the same thermo-electric properties as the thermocouple itself.
  • Helukabel TOPFLEX®-EMV-UV-3-PLUS-2XSLCHK-J

    EMC-preferred type, double screened, enhanced current carrying capacity

    Technical Data PVC motor supply cable acc. to  UL Std.1277 and UL Std.227
    Temperature Range -25°C to +90°C
    Nominal Voltage TC 600 V
    WTTC 1000 V
    AC Test Voltage 4000 V
    Minimum Bending Radius flexing 6x cable Ø
    Coupling Resistance max. 250 Ohm/km
  • Helukabel TRAGO / Lift-2S

    Technical Data  Lift hoist control cables with strain bearing  element .                                                                                                        Special PVC-compound for core and jacket, adapted to DIN VDE 0250
    Temperature Range flexing -15 °C to +40 °C
    fixed installation -40 °C to +70 °C
    Nominal Voltage U0/U 300/500 V
    Test Voltage 3000 V
    Minimum Bending Radius approx. 20x cable ø
    Cable Structure Bare copper, fine wire conductors, bunch stranded to DIN VDE 0295 cl. 6, BS 6360 cl. 6 and IEC 60228 cl. 6                                                                                          Special PVC core insulation, YI3 to  DIN VDE 0207 part 4                                                                                                                                    Core coding to DIN VDE 0293
    Green-yellow earth core
    Test Voltage 3000 V
    Application These cables are used as control or feeder cables in lifts and hoists. The special attention given to both production and material quality for
    these cables has made them ideal even for use under extreme conditions.
    HELUKABEL®-Lift-2S has also proven itself to be ideally suited for installation in conveyor systems and manual control units.
    The external steel support wires can be dismounted without damaging the cable insulation.
    = The product is conformed with the EC Low-Voltage Directive 2006/95/EG.

     

  • HELUKAT® 600 CAT.7e S/FTP FRNC STATIC violet 4 x 2 x AWG 23 /1

    Inner conductor Ø: 0,57 mm
    Conductor material: Copper, bare
    Core insulation: Foam-skin-PE
    Core colours: wh/bu, wh/og, wh/gn, wh/bn
    Screen over stranding element: Al-Foil
    Screen 1 over stranding: Cu braid
    Screen 2 over stranding:
    Outer sheath material: FRNC
    Outer diameter: app. 7,5 mmO
    Outer sheath colour: Blue Lilac similar to RAL 4005

  • LKSM-HF

    Conductor
    Stranded copper conductor 1.0-10 mm², IEC 60228 Class 2
    Stranded copper conductor 16-300 mm², IEC 60228 Class 5
    INSULATION
    XLPE, IEC 60092-360
    CABLING
    Cores twisted together. Fillers or dummy cores included in select sizes based on product specifications to obtain symmetrical and round construction.
    BEDDING
    Lapped tape
    ARMOUR
    Copper wire braid, coverage > 90%, IEC 60092-350
    RIP CORD
    For conductors ≥ 16 mm²
    SHEATH
    Polyolefin SHF1, IEC 60092-360
    Standard colour black, other colours on request
    Application
    Armoured power and control cable. For fixed installation in most areas, and on open deck in ships and offshore units.
    RATED VOLTAGE : AC 0,6/1kV (1.2 kV)
                                  : DC 0.9/1.5 kV (if voltage to earth does not exceed 0.9 kV)
    FIRE PERFORMANCE : IEC 60332-1-2
                                         : IEC 60332-3-22
    HALOGEN-FREE : IEC 60754 series
    SMOKE EMISSION : IEC 61034 series
    MIN. INSTALLATION TEMPERATURE : -15 °C
    OPERATING TEMPERATURE : -40 – 80 °C fixed installation
    MAX. CONDUCTOR TEMPERATURE : 90 °C
  • McGill – Cable Trunk

    Material

    • Self-extinguishing PVC. UL94
    • Flammability Rating of V-0

    Color

    • Slotted: Grey (RAL7042)
    • Solid: White (RAL9003)

    Features

    • Smooth edges protect hands & wiring insulation.
    • Recognized Continuous Use Temperature: -40~+70°C
    • UL Listed E492107

    SIZES

    • Slotted sizes (mm) : 25×25, 25×45, 45×45, 45×65, 50×50, 65×65 80×80, 100×100
    • Solid sizes (mm) : 25×25, 50×50

  • Penn Union

    Conductor Range
    Class B & C 600 kcmil – 4 Str.
    Class G 350 kcmil (259/.0368) – #4 (49/.0292)
    Class H 350 kcmil (427/.0286) – #4 (133/.0177)
    Class I 350 kcmil (882/.0201) – #4 (105/.0201)
    Class K 350 kcmil (3458/.0100) – #4 (420/.0100)
    DLO 373 kcmil (925/.0201) – #4 (105/.0201)

    Product Dimensions
    L (in.) 5.45
    W (in.) 3.00
    H (in.) 2.75
    Hex Size 3/8″
    Number of Conductors 2

  • Penn Union BBLU-8S

    Copper Conductor Size
    Copper Conductor Size 8 AWG
    Product Dimensions
    W (in.) 0.41
    C (in.) 0.69
    T (in.) 0.08
    B (in.) 1.06
    L (in.) 2.00
    Stud Hole Size #10
    Installation Tooling
    Color Code Red
    Penn-Union Dieless Tool TDM-250 or TDM-500
    Burndy Die Index No. 6
    Penn-Union Die Catalog No. T-49
    Wire Strip Length 1-3/16″

  • Penn Union BDR-20-025

    Main
    IPS Size 2″

    Tap
    Conductor Range 6 Sol. – 250 kcmil
    Product Dimensions
    L (in.) 5.63
    M (in.) 2.75
    N (in.) 2.50
    Bolt Size 1/2″

  • Penn Union KO-R06

    Standard Conductor Sizes
    ACSR & AL Alloy – Groove A 6, 4, 2, 6/1
    ACSR & AL Alloy – Groove B 6, 4, 2, 6/1
    AL or CU Stranded – Groove A 6, 4, 3-7, 2
    AL or CU Stranded – Groove B 6, 4, 3-7, 2
    AL or CU Solid – Groove A 6, 4, 3, 2
    AL or CU Solid – Groove B 6, 4, 3, 2
    Compact Conductor Sizes
    ACSR – Groove A 6, 4, 3, 2
    ACSR – Groove B 6, 4, 3, 2
    Stranded – Groove A 6, 4, 3, 2
    Stranded – Groove B 6, 4, 3, 2
    Product Dimensions
    L (in.) 1.50
    W (in.) 0.70
    H (in.) 1.13
    Installation Tooling
    Die Size O
    No. of Crimps – Mechanical Tool 4
    No. of Crimps – Hydraulic Tool 2
    Other
    Program Number 1

  • Penn Union SEL-8

    Conductor Size/Range
    Equal Main & Tap 16 Str. – 8 Str.
    Min. Tap w/ Max. Main 16 Str.

    Product Dimensions
    L (in.) 0.84
    W (in.) 0.50
    B (in.) 0.38
    A (in.) 0.14
    Torque
    Torque (in.-lbs.) 80

  • Penn Union SLB-0513-D

    Stud Thread Size
    Stud Thread Size 1/2″ – 13
    Product Dimensions
    L (in.) 5.25
    M (in.) 1.75
    T (in.) 0.25
    Bolt Size 3/8