Showing 25–36 of 174 results
- 
	
Conductor
Solid copper conductor 24 AWG/1
INSULATION : Solid PE
FIRE PERFORMANCE : Dca s2, d2, a1 IEC 60332-3-24
MAX. CONDUCTOR RESISTANCE (DC) : 93.8 Ω∕km @ 20 °C
MAX. CONDUCTOR RESISTANCE (LOOP) (PAIR, MAX 20 °C) (OHM/KM) : max. 19Ω/100m @20 °C
NOM. MUTUAL CAPACITANCE (NF/KM) : nom. 5.6 nF/100 m
CAPACITANCE UNBALANCE PAIR TO GROUND : ≤330 pF/km @1kHz
MIN. INSULATION RESISTANCE (20 °C) : max. 5000 MΩxkm
CHARACTERISTIC IMPEDANCE : 100±25Ω@100 MHz
RATED TEMPERATURE : 75 °C
OPERATING TEMPERATURE : -20 – 75 °C
  
- 
	

Technical Data
PVC single cores to DIN VDE 0285-525-2-31 /
DIN EN 50525-2-31 and IEC 60227-3
Temperature Range
• flexible +5°C to +70°C
• fixed -30°C to +80°C
Nominal Voltage
AC U0/U 450/750 V
Test Voltage
2500 V
Minimum Bending Radius:
• fixed
• <8 mm: 4x Outer-ø
• 8-12 mm: 5x Outer-ø
• >12 mm: 6x Outer-ø
Cable Structure
• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 / IEC 60228 Class 5
• Core insulation: PVC acc. to DIN VDE 0207-363-3 / DIN EN 50363-3 (compound type TI1)
• Core identification: see datasheet
Test
• flame-retardant acc. to DIN VDE 0482-332-1-2 / DIN EN 60332-1-2 / IEC 60332-1-2
• certifications and approvals:
• H05V-K: HAR
• H05V-K: EAC
Application
Installation in electrical conduits, on or under plaster or similar enclosed systems. Suitable for protected and fixed installation in lighting systems or switching and control devices up to and including 1000 V AC voltage or up to 750 V DC voltage against earth. Not suitable for direct laying in cable ladders and cable trays, except as a potential equalization cable.
  
- 
	

Technical Data
PVC single core, H07V-K acc. to DIN VDE 0285-525-2-31 / DIN EN 50525-2-31, IEC 60227-3; 07V-K in alignment with DIN VDE 0285-525-2-31 / DIN EN 50525-2-31, IEC 60227-3
Temperature Range
• flexible +5°C to +70°C
• fixed -30°C to +80°C
Nominal Voltage
AC U0/U 450/750 V
Test Voltage
2500 V
Minimum Bending Radius:
• fixed
• <8 mm: 4x Outer-ø
• 8-12 mm: 5x Outer-ø
• >12 mm: 6x Outer-ø
Cable Structure
• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 / IEC 60228 Class 5
• Core insulation: PVC acc. to DIN VDE 0207-363-3 / DIN EN 50363-3 (compound type TI1)
• Core identification: see datasheet
Test
• flame-retardant acc. to DIN VDE 0482-332-1-2 / DIN EN 60332-1-2 / IEC 60332-1-2
• certifications and approvals:
• H07V-K: HAR
• H07V-K: EAC
Application
Installation in electrical conduits, on or under plaster or similar enclosed systems. Suitable for protected and fixed installation in lighting systems or switching and control devices up to and including 1000 V AC voltage or up to 750 V DC voltage against earth. Not suitable for direct laying in cable ladders and cable trays, except as a potential equalization cable.
  
- 
	

| Description | 
PVC control and connection cable in alignment with DIN VDE 
0285-525-2-51 / DIN EN 50525-2-51 | 
| Cable Structure | 
Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 / IEC 60228 Class 5 • Core insulation: PVC, compound type Z 7225 • Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits • Protective conductor: starting with 3 cores, G = with protective conductor GN-YE, in the outer layer, x = without protective conductor (OZ) • Cores stranded in layers with optimal lay lengths • Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 / DIN EN 50363-4-1 (compound type TM2) • Sheath colour: grey (RAL 7001) • Length marking: in metres | 
| Test | 
flame-retardant acc. to DIN VDE 0482-332-1-2 / DIN EN 60332- 
1-2 / IEC 60332-1-2 
certifications and approvals: 
EAC 
VDE-Reg.-No. 7032, valid for temperature range up to +70°C | 
| Application | 
Used for flexible applications involving medium mechanical stress 
with free movement, without tensile stress and without forced 
motion control in dry, damp and wet rooms, however, not suitable 
for outdoor use. Used as a connection and control cable in machine 
tools, assembly lines and conveyor belts, production lines, in plant 
construction, air-conditioning technology, in smelters and steel 
mills. Select PVC comp | 
  
- 
	

 | 
 | 
| Description | 
PVC control and connection cable in alignment with DIN VDE 0285-525-2-51 / DIN EN 50525-2-51 | 
| Cable Structure | 
Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 / IEC 60228 Class 5 
Core insulation: PVC, compound type Z 7225 
Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits 
Protective conductor: starting with 3 cores, 
G = with protective conductor GN-YE, in the outer layer, 
x = without protective conductor (OZ) 
Cores stranded in layers with optimal lay lengths 
Foil wrapping 
Screen: 
1 core(s): helically wound tinned copper wires, approx. coverage 85 % 
2 – 100 core(s): braided screen of tinned copper wires, approx. coverage 85 % 
Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 / DIN EN 50363-4-1 (compound type TM2) 
Sheath colour: grey (RAL 7001) 
Length marking: in metres | 
| Test | 
flame-retardant acc. to DIN VDE 0482-332-1-2 / DIN EN 60332-1-2 / IEC 60332-1-2 
certifications and approvals: 
2 – 100 core(s): EAC 
2 – 100 core(s): VDE-Reg.-No. 7034, valid for temperature range up to +70°C | 
| Application | 
For flexible use with free movement without tensile stress or forced movements in dry, moist and wet rooms but not outside; to be used as control and connecting cable in control and regulation technology, in the tool and machine building industry, in computer systems, as well as a signal cable in the electronic industry. A stabilizing foil separator between wire bound and braid reduces the outer diameter essentially and allows for smaller bending radius as well as lower weights. The disturbance free transmission of signals and impulses is ensured due to the high degree of screening. EMC = Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding. | 
 | 
 | 
 | 
 | 
  
- 
	

| Technical Data | 
Rubber connection cable, H07RN-F acc. to DIN VDE 0285- 525-2-21 / DIN EN 50525-2-21; 07RN-F in alignment with DIN VDE 0285-525-2-21 / DIN EN 50525-2-21 | 
| Temperature Range | 
flexible -25°C to +60°C 
fixed -30°C to +60°C | 
| Nominal Voltage | 
AC U0/U 450/750 V | 
| Test Voltage | 
2500 V | 
| Minimum Bending Radius | 
fixed 4x Outer-Ø 
flexible, guidance via roles 7.5x 
Outer-Ø 
flexible, winding on drums 5x 
Outer-Ø | 
 | 
| Cable Structure | 
• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 / 
IEC 60228 Class 5 
• Core insulation: rubber acc. to DIN VDE 0207-363-1 / 
DIN EN 50363-1 (compound type EI4) | 
 | 
 | 
 | 
• Core identification acc. to DIN VDE 0293-308, 
1 core(s): black 
2 – 5 core(s): colour coded 
7 – 37 core(s): black cores with consecutive labeling in white digits 
• Protective conductor: starting with 3 cores, 
G = with protective conductor GN-YE, in the outer layer, 
x = without protective conductor 
• Cores stranded in layers with optimal lay lengths 
• Outer sheath: rubber acc. to DIN VDE 0207-363-2-1 / 
DIN EN 50363-2-1 (compound type EM2) 
• Sheath colour: blac | 
 | 
 | 
 | 
| Test | 
• flame-retardant acc. to DIN VDE 0482-332-1-2 / DIN EN 60332- 
1-2 / IEC 60332-1-2 
• oil-resistant acc. to DIN VDE 0473-811-404 / DIN EN 60811-404 
/ IEC 60811-404 
• certifications and approvals: 
H07RN-F: HAR 
EAC | 
 | 
 | 
| Application | 
Heavy duty, rubber sheathed cable for use with medium mechanical 
stress in dry, damp, wet rooms, in agricultural premises and outdoors. Suitable for equipment in commercial operations, e.g. heating 
plates, hand lamps, electric tools such as drills or circular saws. For 
fixed installation on plaster as well as in temporary constructions. When installed in pipes or similar enclosed systems, the use of 
the cable is permitted up to and including 1000 V AC voltage or up to 
750 V DC voltage against earth. | 
 | 
 | 
 
  
- 
	

| Description | 
Industrial Ethernet cable / Cat. 6 acc. to ISO/IEC 11801, DIN EN 50173, IEC 61156-6, DIN EN 50288-5-2, UL-Std. 444 (CMX), CSA-Std. C22.2 No. 214 – CMX, UL-Std. 758 (AWM) Style 21576 | 
| Cable Structure | 
Copper wire tinned, AWG sizes 
Core insulation: PP 
Core identification: colour coded, pairs: 
No. 1: white-blue / blue 
No. 2: white-orange / orange 
No. 3: white-green / green 
No. 4: white-brown / brown 
Cores stranded in pairs with optimal lay lengths 
Pairs with optimal lay lengths stranded around a central cross-shaped filler 
Inner sheath: halogen-free, flame retardant compound (FRNC) 
1. Screen: plastic-coated aluminium foil (St) 
2. Screen: braided screen of tinned copper wires 
Outer sheath: PUR 
Sheath colour: green 
Length marking: in metres | 
| Test | 
halogen-free acc. to DIN VDE 0482-754-1 / DIN EN 60754-1 / IEC 60754-1 
flame-retardant acc. to DIN VDE 0482-332-1-2 / DIN EN 60332-1-2 / IEC 60332-1-2 
certifications and approvals: 
EAC 
Notes | 
| Application | 
HELUKAT 250S CAT.6 CMX SF/UTP PUR CHAIN is designed for use in cable carriers and the recurring loads caused by moving machine components. It provides excellent transmission characteristics under extremely difficult conditions. | 
 | 
 | 
 | 
 | 
  
- 
	
| Cable Structure | 
Type DMX cables 
Cable structure (1x2x0,24)+2×1,0 
Conductor material: Copper, bare 
Core insulation: Foam-Skin-PE (DMX), PVC (Power) 
Core colours: red, white (DMX); yellow, green (Power) 
Stranding element: 2 cores with 1 filler 
Sheath material: PVC soft 
Cable external diameter: approx. 7,4 mm 
Sheath colour: black matt | 
 | 
 | 
 | 
 | 
 | 
 | 
| Application | 
The hybrid DMX Power cable is used in the professional DMX light controller. It transmits power for the light and control signals for the movement. 
The cable is compact, flexible and easy to process. | 
  
- 
	

| Technical Data | 
PVC connection cable, acc. to UNE 21123-2; articles with 3+1/2 conductors: in alignment with UNE 21123-2 | 
 | 
direct burial | 
 | 
XLPE core insulation / 90°C | 
| Test | 
flame-retardant acc. to DIN VDE 0482-332-1-2 / DIN EN 60332-1-2 / IEC 60332-1-2 
UV-resistant acc. to DIN VDE 0276-605 / HD 605 S2 | 
| Cable Structure | 
Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 / IEC 60228 Class 5 
Core insulation: XLPE acc. to UNE-HD 603-1 (compound type DIX 3) 
Core identification: see datasheet 
G = with protective conductor GN-YE, in the outer layer, 
x = without protective conductor 
Cores stranded in layers with optimal lay lengths 
Outer sheath: PVC acc. to UNE HD 603-1 (compound type DMV 18) 
Sheath colour: black 
Length marking: in metres | 
 | 
 | 
| Application | 
Suitable for use in dry, moist and wet rooms as well as outdoors. Also suitable for direct burial, laying in tubes and underground installation areas. Typical application areas range from general production machinery, to machine tool applications, conveyor belt systems, air-conditioning units, steel plants installations and factory automation. Ideal as power or control cable especially if increased temperature and/or voltage is required. UV resistant due to it’s special PVC outer sheath compound and therefore also ideal as power connection cable for outdoor devices and machinery. Alternatively also for use as power connection cable in the stage and lighting industry or renewable energy sector. | 
 | 
 | 
 | 
 | 
 | 
  
- 
	

| Technical Data | 
Special cable in reference to 
DIN VDE 0250 / DIN VDE 0285-525-1 / 
DIN EN 50525-1 | 
| Temperature Range | 
flexing  -25°C  to  +50°C 
fixed installation  -40°C  to  +80°C | 
| Nominal Voltage | 
U0/U 450/750 V | 
| Test Voltage | 
2,5 kV | 
| Minimum Bending Radius | 
fixed installation 5x outer Ø | 
 | 
| Cable Structure | 
Bare copper conductor, 
fine wire acc. to 
DIN VDE 0295 cl.5 / IEC 60228 cl.5                                                                                                                                                                                                     Core insulation of PVC 
Core identification  acc. to DIN VDE 0293-308 
1 core: black 
≤ 5 cores: coloured                                                                                                                                                                                                                                                      GN-YE conductor, 3 cores and above                                                                                                                                                                                                                Outer sheath of cross-linked special compound                                                                                                                                                                                                       Sheath colour: blue (RAL 5015) | 
 | 
 | 
| Application | 
Useful for average mechanical stresses in continuously submerging pump lines for drinking and utility water, with a maximum immersion depth of 
600 m. Useful as a connection cable in processing plants in the food and beverage industry, as well as fishponds and aquariums. 
= Product conforms with Low-Voltage Directive 2014/35/EU. | 
 | 
 | 
 | 
 | 
 | 
  
- 
	
| Cable Structure | 
Conductor material: Copper, bare 
Core insulation: FRNC 
Core colours: rd, bk 
Stranding element: pairs stranded 
Sheath material: FRNC 
Cable external diameter: approx. 6,6 mm 
Sheath colour: black | 
| Application | 
The safe solution for increasing demands on the security in case of fire, as flame retardant, low smoke, halogen-free, no corrosion damage by released 
gases and fumes, no flame propagation provide for local flame propagation for the integrity of important systems. | 
 
  
- 
	
| Description | 
 Class 5 bare Cu-conductor (IEC 60228) 
Very Flexible; minimal bending radius 
Available in different electrical primary color 
Special TI1 PVC insulation 
Flame retardant per IEC 60332-1 
≈10 MOhm x km insulation resistance 
Nominal voltage up to 1000V 
750V direct current against earth 
Harmonized CE approved product conformed with EC 
low voltage directive 2006/95/EC 
100mtr/box available for size ≤10mm² 
High ambient temperature compare to other local type 
•GN-YE grounding conductor is also available |