Show Sidebar

Cables and Cable Management

Showing 13–24 of 174 results

  • Basor Cover TBFR (BF2R H65)

  • Basor Fastening Clip

  • Basor Set Splice Plate Bend

  • Bolt Nut Set ( CTBF)

    BF BOLT-NUT SET EZ
    REF: 2/4362
    WEIGHT: 0.03

  • CAT 6A U/FTP 4 PR AWG 23/1

    Conductor
    Solid copper conductor 23 AWG/1

    INSULATION : Foam PE

    FIRE PERFORMANCE : Dca s2, d2, a1 IEC 60332-3-24

    MAX. CONDUCTOR RESISTANCE (DC) : 95 Ω∕km @ 20 °C

    MAX. CONDUCTOR RESISTANCE (LOOP) (PAIR, MAX 20 °C) (OHM/KM) : max. 19Ω/100m @20 °C

    NOM. MUTUAL CAPACITANCE (NF/KM) : nom. 5.6 nF/100 m

    CAPACITANCE UNBALANCE PAIR TO GROUND : ≤160 pF/km @1kHz

    MIN. INSULATION RESISTANCE (20 °C) : > 5000 MΩxkm

    CHARACTERISTIC IMPEDANCE : 100±5Ω@100 MHz

    RATED TEMPERATURE : 75 °C

    OPERATING TEMPERATURE : -20 – 75 °C

  • CMP A2 Cable Gland

    A2 | Industrial Cable Gland

    For all types of Unarmoured & Braid Armoured Cables

    Features
    • High quality durable materials
    • Robust, heavy duty design
    • Displacement type seal
    • Deluge protected
    • -60°C to +130°C (standard), -20°C to 200°C (ThermIn option, see A2HT)

  • CMP A2F Cable Gland

    For Explosive Atmosphere | Ex eb, Ex db, Ex nR, Ex taFor all types of Unarmoured & Braid Armour Cables
    Globally Approved, Explosive Atmosphere Cable Gland
    • Displacement type flameproof seal
    • Deluge protected
    • -60°C to +130°C
    • Globally marked, IECEx, ATEX & CSA

  • CMP Cable Cleats Sovereign (HDSS)

    Third party certification to IEC 61914
    316L stainless steel
    17 – 128mm in 24 sizes for trefoil formation /application
    Short circuit rating of 190kA peak fault
    Operating temperature -60°C to +60°C
    Standard Polymer Liners are classified as Low Smoke
    and Fume Zero Halogen (LSF0H), Phosphorus-free
    Combined single (M12) and two bolt (M10) fixing design

  • CMP Cable Gland CW

    For all types of Steel & Aluminium Wire Armoured Cable
    Single Seal Industrial Cable Gland
    • High quality durable materials
    • Robust, heavy duty design
    • Metal-to-metal armour clamping
    • Direct & remote installation
    • Controlled outer ‘load retention’ seal
    • Unique OSTG prevents overtightening
    • -60°C to +130°C (standard), -20°C to 200°C (ThermIn option CWHT)
    • Deluge protection option
    • EMC tested

  • CMP Cable Gland EFW

    • Metal-to-metal armour clamping
    • Direct & remote installation
    • Displacement type flameproof inner seal
    • Controlled outer ‘load retention’ seal
    • Unique OSTG prevents overtightening
    • Designed to prevent coldflow, see CMP Technical Document TS001 (available upon request)
    • -60°C to +130°C
    • Class I Zone 1, 21 and Zone 2, 22 Class I Division 2 ABCD
    • Globally marked, IECEx, ATEX & cCSAus
    • EMC tested

  • CMP Falcon Nylon Cable Cleat

    Third party certification to IEC 61914
    Available in three different materials:
    • Nylon
    • Low Smoke & Fume (LSF), Zero Halogen (LS0H, Phosphorus Free and V0 Nylon
    • LUL approved polymer
    Sunlight (UV) & weather resistant
    Operating temperature -40°C to +60°C
    Can be double stacked
    38 – 135mm in 8 sizes
    Excellent axial & lateral load retention
    Two bolt fixing design

  • Helkama – H-FLEX PWR PUR

    CONDUCTOR
    Stranded copper conductor 1.0-300 mm², IEC 60228 class 5

    INSULATION
    XPLE plastic

    BEDDING
    Non-woven separator tape

    SHEATH
    • Polyurethane compound
    • Standard colour black, other colours on request

    RATED VOLTAGE
    • AC 0.6/1 kV (1.2 kV)
    • DC 0.9/1.5 kV (if voltage to earth does not exceed 0.9 kV)