Showing 13–24 of 174 results
-
CAT 6A U/FTP 4 PR AWG 23/1
Conductor
Solid copper conductor 23 AWG/1INSULATION : Foam PE
FIRE PERFORMANCE : Dca s2, d2, a1 IEC 60332-3-24
MAX. CONDUCTOR RESISTANCE (DC) : 95 Ω∕km @ 20 °C
MAX. CONDUCTOR RESISTANCE (LOOP) (PAIR, MAX 20 °C) (OHM/KM) : max. 19Ω/100m @20 °C
NOM. MUTUAL CAPACITANCE (NF/KM) : nom. 5.6 nF/100 m
CAPACITANCE UNBALANCE PAIR TO GROUND : ≤160 pF/km @1kHz
MIN. INSULATION RESISTANCE (20 °C) : > 5000 MΩxkm
CHARACTERISTIC IMPEDANCE : 100±5Ω@100 MHz
RATED TEMPERATURE : 75 °C
OPERATING TEMPERATURE : -20 – 75 °C
-
CMP A2 Cable Gland
A2 | Industrial Cable Gland
For all types of Unarmoured & Braid Armoured Cables
Features
• High quality durable materials
• Robust, heavy duty design
• Displacement type seal
• Deluge protected
• -60°C to +130°C (standard), -20°C to 200°C (ThermIn option, see A2HT)
-
CMP A2F Cable Gland
For Explosive Atmosphere | Ex eb, Ex db, Ex nR, Ex taFor all types of Unarmoured & Braid Armour Cables
Globally Approved, Explosive Atmosphere Cable Gland
• Displacement type flameproof seal
• Deluge protected
• -60°C to +130°C
• Globally marked, IECEx, ATEX & CSA -
CMP Cable Cleats Sovereign (HDSS)
Third party certification to IEC 61914
316L stainless steel
17 – 128mm in 24 sizes for trefoil formation /application
Short circuit rating of 190kA peak fault
Operating temperature -60°C to +60°C
Standard Polymer Liners are classified as Low Smoke
and Fume Zero Halogen (LSF0H), Phosphorus-free
Combined single (M12) and two bolt (M10) fixing design -
CMP Cable Gland CW
For all types of Steel & Aluminium Wire Armoured Cable
Single Seal Industrial Cable Gland
• High quality durable materials
• Robust, heavy duty design
• Metal-to-metal armour clamping
• Direct & remote installation
• Controlled outer ‘load retention’ seal
• Unique OSTG prevents overtightening
• -60°C to +130°C (standard), -20°C to 200°C (ThermIn option CWHT)
• Deluge protection option
• EMC tested -
CMP Cable Gland EFW
• Metal-to-metal armour clamping
• Direct & remote installation
• Displacement type flameproof inner seal
• Controlled outer ‘load retention’ seal
• Unique OSTG prevents overtightening
• Designed to prevent coldflow, see CMP Technical Document TS001 (available upon request)
• -60°C to +130°C
• Class I Zone 1, 21 and Zone 2, 22 Class I Division 2 ABCD
• Globally marked, IECEx, ATEX & cCSAus
• EMC tested -
CMP Falcon Nylon Cable Cleat
Third party certification to IEC 61914
Available in three different materials:
• Nylon
• Low Smoke & Fume (LSF), Zero Halogen (LS0H, Phosphorus Free and V0 Nylon
• LUL approved polymer
Sunlight (UV) & weather resistant
Operating temperature -40°C to +60°C
Can be double stacked
38 – 135mm in 8 sizes
Excellent axial & lateral load retention
Two bolt fixing design -
Helkama – H-FLEX PWR PUR
CONDUCTOR
Stranded copper conductor 1.0-300 mm², IEC 60228 class 5INSULATION
XPLE plasticBEDDING
Non-woven separator tapeSHEATH
• Polyurethane compound
• Standard colour black, other colours on requestRATED VOLTAGE
• AC 0.6/1 kV (1.2 kV)
• DC 0.9/1.5 kV (if voltage to earth does not exceed 0.9 kV)