  • Helukabel H07RN-F / 07RN-F

    Technical Data Rubber connection cable, H07RN-F acc. to DIN VDE 0285- 525-2-21 / DIN EN 50525-2-21; 07RN-F in alignment with DIN VDE 0285-525-2-21 / DIN EN 50525-2-21
    Temperature Range flexible -25°C to +60°C
    fixed -30°C to +60°C
    Nominal Voltage AC U0/U 450/750 V
    Test Voltage 2500 V
    Minimum Bending Radius fixed 4x Outer-Ø
    flexible, guidance via roles 7.5x
    Outer-Ø
    flexible, winding on drums 5x
    Outer-Ø
    Cable Structure • Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 /
    IEC 60228 Class 5
    • Core insulation: rubber acc. to DIN VDE 0207-363-1 /
    DIN EN 50363-1 (compound type EI4)
    • Core identification acc. to DIN VDE 0293-308,
    1 core(s): black
    2 – 5 core(s): colour coded
    7 – 37 core(s): black cores with consecutive labeling in white digits
    • Protective conductor: starting with 3 cores,
    G = with protective conductor GN-YE, in the outer layer,
    x = without protective conductor
    • Cores stranded in layers with optimal lay lengths
    • Outer sheath: rubber acc. to DIN VDE 0207-363-2-1 /
    DIN EN 50363-2-1 (compound type EM2)
    • Sheath colour: blac
    Test • flame-retardant acc. to DIN VDE 0482-332-1-2 / DIN EN 60332-
    1-2 / IEC 60332-1-2
    • oil-resistant acc. to DIN VDE 0473-811-404 / DIN EN 60811-404
    / IEC 60811-404
    • certifications and approvals:
    H07RN-F: HAR
    EAC
    Application Heavy duty, rubber sheathed cable for use with medium mechanical
    stress in dry, damp, wet rooms, in agricultural premises and outdoors. Suitable for equipment in commercial operations, e.g. heating
    plates, hand lamps, electric tools such as drills or circular saws. For
    fixed installation on plaster as well as in temporary constructions. When installed in pipes or similar enclosed systems, the use of
    the cable is permitted up to and including 1000 V AC voltage or up to
    750 V DC voltage against earth.

     

  • Helukabel NSSHÖU heavy dusty rubber cable 0,6/1kV

    Technical Data Rubber sheath cable to DIN VDE 0250 part 812
    Temperature Range flexing -25°C to +80°C
    fixed installation -40°C to +80°C
    ● Resistant against hot penetration
    ● Core insulation of rubber (EPR)
    compound type 3GI3 to
    DIN VDE 0207 part 20
    ● Low abrasion
    ● High notch resistant
    ● Permissible operating temperature
    at conductor +90°C
    Nominal Voltage U0/U 0,6/1 kV
    Test Voltage 3000 V
    Minimum Bending Radius fixed installation 4x cable Ø
    flexing 10x cable Ø
    without forced operation 15x cable Ø
    Cable Structure Tinned copper-conductor, to
    DIN VDE 0295 cl.5, fine-wire,
    BS 6360 cl.5, IEC 60228 cl.5
    Core insulation of rubber (EPR)
    compound type 3GI3 to DIN VDE 0207 part 20
    Core identification to DIN VDE 0293-308
    – up to 5 cores coloured
    – from 6 cores, black with continuous white numbering
    GN-YE conductor,  3 cores and above
    Cores stranded in layers with optimal lay-length
    Test Behaviour in fire to DIN VDE 0482-332-1-2 DIN EN 60332-2-1, IEC 60332-1 (equivalent
    DIN VDE 0472 part 804 test method B) Oil resistant to DIN EN 60811-404
  • Helukabel TRAGO / Lift-2S

    Technical Data  Lift hoist control cables with strain bearing  element .                                                                                                        Special PVC-compound for core and jacket, adapted to DIN VDE 0250
    Temperature Range flexing -15 °C to +40 °C
    fixed installation -40 °C to +70 °C
    Nominal Voltage U0/U 300/500 V
    Test Voltage 3000 V
    Minimum Bending Radius approx. 20x cable ø
    Cable Structure Bare copper, fine wire conductors, bunch stranded to DIN VDE 0295 cl. 6, BS 6360 cl. 6 and IEC 60228 cl. 6                                                                                          Special PVC core insulation, YI3 to  DIN VDE 0207 part 4                                                                                                                                    Core coding to DIN VDE 0293
    Green-yellow earth core
    Test Voltage 3000 V
    Application These cables are used as control or feeder cables in lifts and hoists. The special attention given to both production and material quality for
    these cables has made them ideal even for use under extreme conditions.
    HELUKABEL®-Lift-2S has also proven itself to be ideally suited for installation in conveyor systems and manual control units.
    The external steel support wires can be dismounted without damaging the cable insulation.
    = The product is conformed with the EC Low-Voltage Directive 2006/95/EG.